Fix presonus eris e5 , stopped working after a minor power fluctuation . i knew that there could be a small issue may be a fuse is gone. but the external fuse was fine. However there is internal fuse in the transformer that was the issue.
(WARNING : do this fixing at your own risk . if you are not sure then see a repair person)
STEP1: Check for cable / use multimeter if there is power coming. Check for External fuse behind the monitor if that fine.
IF THERE IS STILL NO POWER*******
OPENING BOX - When i opened box I noticed that there are no burn it was like new so i was sure there is some internal fuse which is gone.
STEP2: -- Open the box carefully. Check AC power .. if the AC power is coming OK . then use Multimeter on continuity mode for the Transformer Output. if continuity power of monitor is zero . it means there is something cut off may be a fuse.
(if you do not have a multimeter thats also ok . if you are sure there is no burn)
STEP3: open the transformer , look for fuse and you may replace or directly join it. and pack the transformer carefully with plastic tape so that there is no current leakage.
Смотрите видео Fix presonus eris e5 , no power issue . No blue light . Fixing internal fuse fix онлайн без регистрации, длительностью часов минут секунд в хорошем качестве. Это видео добавил пользователь Codician 19 Июнь 2024, не забудьте поделиться им ссылкой с друзьями и знакомыми, на нашем сайте его посмотрели 2,117 раз и оно понравилось 22 людям.