LISTEN WITH HEADPHONES. Recording made with a Thinklabs One Digital Stethoscope. Auscultation of moderate mitral regurgitation in a patient with atrial fibrillation. Note the holosystolic high pitched murmur, which does not vary in loudness despite the irregular cycle lengths; this classic finding proves the murmur is from regurgitation, not from ejection, and can easily distinguish the murmurs of aortic stenosis and mitral regurgitation.
Contributor: Terry Bauch, MD, Geisinger Medical Center
For more information, visit our website: http://www.thinklabs.com/
Copyright Notice: You may use sounds from this library with written permission from Thinklabs. We usually grant permission on condition that correct attribution is provided and you include a link to thinklabsmedical.com. Contact us for more information.